How does penetrant testing (PT) work?
In penetrant testing, W.S. Werkstoff Service examines components non-destructively for surface-breaking defects such as cracks or pores. First, the surface is thoroughly cleaned so that dirt, oil or residues do not affect the results. A red or fluorescent penetrant is then applied and enters any defects present. After excess penetrant is removed, a developer is applied to draw the penetrant out of the defects and make it visible on the surface. The indications are evaluated visually or under UV light. Finally, the component is cleaned and the test results are documented in accordance with the applicable standards.